H2S Strip Test Kit

Directions For Use With Schematic Diagrams

Precautions
1. Carry out the test at neat and clean place.
2. Wash your hands with soap and water before carrying out the test.
3. Remember. Do Not Touch the inner surface of the Bottle and the cap.
Unseal the H2S Strip Test Kit's bottle.
Fill the bottle up to 20 ml mark with sample water.
Keep the bottle at room temperature for 24 hours.
Observe after 24 hours. If water color turns black, indicating the presence of H2S producing bacteria and the water from that source is not safe for drinking purpose. There is possibility of presence of harmful bacteria in the water. Chlorinate or boil the water before drinking.

No change in water color indicates that the water from that source is safe for drinking.